Omron 3G3MV-PDRT2 User Manual page 298

Devicenet communications units
Table of Contents

Advertisement

Appendices
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
n138
018A
01
n139
018B
01
n140
018C
01
n141
018D
01
n142
018E
01
n143
018F
01
n144
0190
01
n145
0191
01
n146
0192
01
n147
---
---
n148
n149
0195
01
n150
0196
01
n151
0197
01
n152
0198
01
n153
0199
01
n154
019A
01
n155
019B
01
n156
019C
01
n157
019D
01
n158
019E
01
n159
019F
01
n160
01A0
01
n161
01A1
01
n162
01A2
01
n163
01A3
01
n164
01A4
01
n165
---
---
n166
01A6
01
n167
01A7
01
n168
01A8
01
10-40
Name
At-
tribute
8A
Feedback loss detection time
8B
Energy-saving control selection
8C
Energy-saving control coefficient K2
8D
Energy-saving voltage lower limit at 60-
Hz output
8E
Energy-saving voltage lower limit at 6-
Hz output
8F
Power averaging time
90
Probe operation voltage limit
91
Probe operation control voltage step at
100%
92
Probe operation control voltage step at
5%
---
Not used.
95
Pulse train input scale
96
Multi-function analog output, pulse train
frequency selection
97
RS-422/485 communications time-over
detection selection
98
RS-422/485 communications fre-
quency reference/monitor unit selection
99
RS-422/485 communications slave
address (read only)
9A
RS-422/485 baud rate selection (read
only)
9B
RS-422/485 parity selection (read only) 0 to 2
9C
RS-422/485 send wait time (read only) 10 to 65
9D
RS-422/485 RTS control selection
9E
Motor code
9F
Energy-saving voltage upper limit at
60-Hz output
A0
Energy-saving upper limit voltage at 6-
Hz output
A1
Power detection width for probe opera-
tion switching
A2
Power detection filter constant
A3
PID output gain
A4
PID feedback input block selection
---
Not used.
A6
Open input phase detection level
A7
Open input phase detection time
A8
Open output phase detection level
Chapter 10
Setting
Setting
Default
range
unit
setting
0.0 to
0.1 s
1.0
25.5
0, 1
1
0
0.0 to
0.1
Differs
6550
with
capacity.
0 to 120
1%
50
0 to 25
1%
12
1 to 200
1
1
(24 ms)
0 to 100
1%
0
0.1 to
0.1%
0.5
10.0
0.1 to
0.1%
0.2
10.0
---
---
---
100 to
1 (10 Hz) 2500
3300
0, 1, 6,
1
0
12, 24,
36, 40 to
45
0 to 4
1
0
0 to 3
1
0
00 to 32
1
00
0 to 3
1
2
1
0
1 ms
10
0, 1
1
0
0 to 70
1
Differs
with
capacity.
0 to 120
1%
120
0 to 25
1%
16
0 to 100
1%
10
0 to 255
1 (4 ms)
5
0.0 to
0.1
1.0
25.0
0 to 5
1
0
---
---
---
0 to 100
1%
0
0 to 255
1 s
0
0 to 100
1%
0
Write
during
opera-
tion
No
No
No
No
No
No
No
No
No
---
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
---
No
No
No