Omron 3G3MV-PDRT2 User Manual page 144

Devicenet communications units
Table of Contents

Advertisement

Message Communications
Instance
Attribute
01
07
Speed Actual
Rotational
Speed Monitor
(See notes 2
and 4.)
08
Speed Refer-
ence
Rotational
Speed Refer-
ence
(See notes 2
and 4.)
09
Current Actual
0F
Power Actual
6-14
Name
Content
The output frequency
monitor (U-02/U1-02) can
be monitored in hexadeci-
mal with the minimum unit
as 1 hex.
The frequency monitor's
minimum unit can be set
by the frequency refer-
ence setting and display
units in n035/o1-03.
n035/o1-03 = 0: 0.01 Hz
n035/o1-03 = 1: 0.01%
(100%: Max. frequency.)
n035/o1-03 = 2 to 39:
1 r/min
n035/o1-03 = 40 to 3,999:
Follow individual set val-
ues.
When r/min units are
being used, a multiplier
can be set in attribute 16
(the Speed Scale setting).
Can be set and read in
hexadecimal with the fre-
quency reference mini-
mum unit as 1 hex.
The frequency reference
minimum unit can be set
by the frequency refer-
ence setting and display
units in n035/o1-03.
n035/o1-03 = 0: 0.01 Hz
n035/o1-03 = 1: 0.01%
(100%: Max. frequency.)
n035/o1-03 = 2 to 39:
1 r/min
n035/o1-03 = 40 to 3,999:
Follow individual set val-
ues.
When r/min units are
being used, a multiplier
can be set in attribute 16
(the Speed Scale setting).
Can be referenced in
hexadecimal with the out-
put current monitor U-03/
U1-03 minimum unit as
0.1 A.
Setting the attribute 17
current scale enables a
multiplication factor to be
set.
Can be referenced in
hexadecimal with the out-
put power monitor U-11/
U1-08 minimum unit as
1 W.
Setting the attribute 1A
power scale enables a
multiplication factor to be
set.
Setting range
Default
---
0000
0 to max. fre-
0000
quency
---
0000
---
0000
Chapter 6
Read
Write
Size
Yes
No
Word
Yes
Yes
Word
Yes
No
Word
Yes
No
Word