Omron 3G3MV-PDRT2 User Manual page 358

Devicenet communications units
Table of Contents

Advertisement

Appendices
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
H3-06
040E
01
H3-07
040F
01
H3-08
0410
01
H3-09
0411
01
H3-10
0412
01
H3-11
0413
01
H3-12
0414
01
H4-01
0415
01
H4-02
0416
01
H4-03
0417
01
H4-04
0418
01
H4-05
0419
01
H4-06
041A
01
H4-07
041B
01
H5-01
041C
---
H5-02
041D
---
H5-03
041E
---
H5-04
041F
---
H5-05
0420
---
Note 1. The values in parentheses indicate initial values when initialized in 3-wire sequence.
Note 2. Within the setting range (1 to 38), 4, 10, 11, 12, 13, 14, 25, 28, 34, and 35 cannot be set,
and 29 to 31 are not used.
Protective Function Parameters
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
L1-01
0480
01
L1-02
0481
01
L2-01
0482
04
L2-02
0483
01
L2-03
0484
01
10-100
Name
At-
tribute
8C
Multi-function analog input signal gain:
terminal 16
8D
Multi-function analog input signal bias:
terminal 16
8E
Frequency reference (current) signal
selection: terminal 14
8F
Frequency reference (current) selec-
tion: terminal 14
90
Frequency reference (current) gain: ter-
minal 14
91
Frequency reference (current) bias: ter-
minal 14
92
Analog input filter time constant
93
Multi-function analog output 1 selec-
tion: terminal 21
94
Multi-function analog output 1 gain ter-
minal 21
95
Multi-function analog output 1 bias ter-
minal 21
96
Multi-function analog output 2 selec-
tion: terminal 23
97
Multi-function analog output 2 gain ter-
minal 23
98
Multi-function analog output 2 bias ter-
minal 23
99
Multi-function analog output signal level
selection
---
Not used.
---
Not used.
---
Not used.
---
Not used.
---
Not used.
Name
At-
tribute
9A
Motor protection selection
9B
Motor protection time constant
9C
Momentary power loss selection
9D
Momentary power loss ridethru
9E
Minimum baseblock time (BB)
Chapter 10
Setting
Setting
Default
range
unit
setting
0.0 to
0.1%
100.0
1000.0
−100.0 to
0.1%
0.0
100.0
0 to 2
1
2
0 to 1F
1
1F
0.0 to
0.1%
100.0
1000.0
−100.0 to
0.1%
0.0
100.0
0.00 to
0.01 s
0.00
2.00
1 to 38
1
2
(See
note 2.)
0.00 to
0.01
1.00
2.50
−10.0 to
0.1%
0.0
10.0
1 to 38
1
3
(See
note 2.)
0.00 to
0.01
0.50
2.50
−10.0 to
0.1%
0.0
10.0
0, 1
1
0
---
---
1F
---
---
3
---
---
0
---
---
3
---
---
1
Setting
Setting
Default
range
unit
setting
0, 1
1
1
0.1 to 5.0 0.1 min
1.0
0 to 2
1
0
0.0 to 2.0 0.1 s
0.7 (See
note 2.)
0.1 to 5.0 0.1 s
0.5 (See
note 2.)
Write
during
opera-
tion
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
No
---
---
---
---
---
Write
during
opera-
tion
No
No
No
No
No

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3rv-pdrt2

Table of Contents