Omron 3G3MV-PDRT2 User Manual page 356

Devicenet communications units
Table of Contents

Advertisement

Appendices
Note 1. Values in parentheses are for 400-V-class Inverters.
Note 2. When the control mode is changed, the Inverter will revert to default settings. (The open loop
vector control default settings are given above.)
Note 3. The default setting depends upon the type of Inverter. The value for a 200-V-class 0.4-kW
Inverter is given above.
Note 4. The setting range is 10% to 200% of the Inverter's rated output current. The values for a 200-
V-class 0.4-kW Inverter are given above.
Note 5. The setting range is 0.00 to (motor's rated current -0.1 A). The value for a 200-V-class 0.4-
kW Inverter is given above.
Option Parameters
Con-
Regis-
Class 64 (hex)
stant
ter num-
In-
ber
stance
(hex)
F1-01
0380
01
F1-02
0381
01
F1-03
0382
01
F1-04
0383
01
F1-05
0384
01
F1-06
0385
01
F1-07
0386
01
F1-08
0387
01
F1-09
0388
01
F1-10
0389
01
F1-11
038A
01
F1-12
038B
01
F1-13
038C
01
F1-14
0397
01
F2-01
038D
---
F3-01
038E
---
F4-01
038F
---
F4-02
0390
---
F4-03
0391
---
F4-04
0392
---
F4-05
03A0
---
F4-06
03A1
---
F5-01
0393
---
F5-02
0394
---
10-98
Name
At-
tribute
70
Number of PG pulses
71
PG disconnection stopping method
(PGO)
72
PG overspeed stopping method
73
PG speed deviation stopping method
74
PG rotation setting
75
PG output ratio
76
Selecting integral control during accel/
decel.
77
Overspeed (OS) detection level.
78
Overspeed (OS) detection time
79
PG speed deviation detection level
(DEV)
7A
PG speed deviation detection time
(DEV)
7B
Number of PG gear teeth 1
7C
Number of PG gear teeth 2
7D
PG disconnection detection time
---
Analog Reference Card selection
---
Digital Reference Card input selection
---
Channel 1 output monitor selection
---
Channel 1 gain
---
Channel 2 output monitor selection
---
Channel 2 gain
---
Channel 1 bias
---
Channel 2 bias
---
Not used.
---
Not used.
Chapter 10
Setting
Setting
Default
range
unit
setting
0 to
1 p/r
1000
60000
0 to 3
1
1
0 to 3
1
1
0 to 3
1
3
0, 1
1
0
0 to 132
1
1
0, 1
1
0
0 to 120
1%
115
0.0 to 2.0 0.1 s
0.0 (See
note 1.)
0 to 50
1%
10
0.0 to
0.1 s
0.5
10.0
0 to 1000 1
0
0 to 1000 1
0
0.0 to
0.1 s
2.0
10.0
0, 1
1
0
0 to 7
1
0
1 to 38
1
2
(See
note 2.)
0.00 to
0.01
1.00
2.50
1 to 38
1
3
(See
note 2.)
0.00 to
0.01
0.50
2.50
−10.0 to
0.1%
0.0
10.0
−10.0 to
0.1%
0.0
10.0
---
---
0
---
---
1
Write
during
opera-
tion
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
Yes
Yes
Yes
---
---