Configurator Settings
Monitoring Methods
■
●
Using the Monitor Device Window
• Click the Warning Torque Tab in the Monitor Device Window.
• The following information will be displayed.
Item
Accel/Decel Torque Cur-
rent
Accel/Decel Peak Torque
Warning Torque during
Accel/Decel
Torque Current during Fre-
quency Agree
Peak Torque during Fre-
quency Agree
Warning Torque during
Frequency Agree
Clear Error Flag Button
Displays the output current monitor value (threshold) level during acceleration/
deceleration.
Displays the maximum output current level during acceleration/deceleration.
Note: The value can be cleared to zero by clicking the Clear Peak Value Button
on the right side of the window.
Displays this item as selected when the output current level exceeds the monitor
value (threshold) during acceleration/deceleration.
Displays the output current monitor value (threshold) level during frequency
agreement.
Displays the maximum output current level during frequency agreement.
Note: The value can be cleared to zero by clicking the Clear Peak Value Button
on the right side of the window.
Displays this item as selected when the output current level exceeds the monitor
value (threshold) during frequency agreement.
Clears the Warning Torque Detection Flag in the Unit's Status Area.
Note: This button is enabled when the Status field is selected on the Warning
Torque Tab Page of the Edit Device Parameters Window.
Warning Torque Tab
Page in the Monitor
Device Window
Details
Chapter 7
7-15