F040
Automatic Function Selection
Program Utilities Display Parameters
This parameter setting is used to configure multiple parameters with the setting
of only one parameter. From the selection below multiple parameters may be
set as indicated in the table.
Once set, the selected configuration is placed in effect and remains in effect
until this parameter is changed or the individual settings are changed.
Set this parameter to Disable to set these parameters individually.
Note:
After performing the desired selection the EOI display returns to
Disabled though the selected function has been carried out (i.e.,
without this, if selection 1 is performed, F004 and F207 would
hold the RR terminal setting regardless of attempts to change the
settings individually).
Settings:
0 — Disabled
1 — RR
2 — VI/II (V/I)
3 — RR or V/I Switched via Terminal Board
4 — Keypad Frequency/Terminal Board Command
5 — Keypad Frequency and Command
Related
Default
0-Disable 1-RR 2-V/I
Params
Settings
Command
Termina
Mode
l Board
F003
Frequency
Mode 1
RR
N/C
F004
S3 Terminal
Preset
F117
Speed 3
Freq.
Termina
Priority
N/C
l Board
F200
V/I
Setup
0.0%
N/C
F201
Frequency
Mode 2
V/I
N/C
F207
Note:
* Go to
F003
and/or
F004
EOI for control.
G9 ASD Installation and Operation Manual
User Settings
4-Keypad/
3-RR or
Freq.
V/I via TB
CMD/TB
Terminal
N/C
Board
RR
N/C
RR
*Keypad
Freq.
N/C
Ref.
Priority
Terminal Board
20.0%
RR
V/I
*Keypad
and select EOI Keypad to use the
Direct Access Number — F040
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
5-Keypad
Freq/CMD
*Keypad
N/C
N/C
F040
85