Toshiba G9 Installation And Operation Manual page 242

Asd
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc
Table 5. Discrete Input Terminal Assignment Selections And Descriptions.
Sel. No.
NO NC
Unassigned — No operation.
0
1
2
3
Forward — Provides a Forward run command.
4
5
Reverse — Provides a Reverse run command.
6
7
Standby — Enables the Forward and Reverse operation commands.
8
9
Reset — Resets the device and any active faults.
10
11
Preset Speed 1 — Preset Speed 1 is used as the LSB of the 4-bit nibble that is used to select a Preset Speed.
Preset Speed 2 — Preset Speed 2 is used as the second bit of the 4-bit nibble that is used to select a Preset Speed.
12
13
14
15
Preset Speed 3 — Preset Speed 3 is used as the third bit of the 4-bit nibble that is used to select a Preset Speed.
16
17
Preset Speed 4 — Preset Speed 4 is used as the MSB of the 4-bit nibble that is used to select a Preset Speed.
Jog Run — This terminal activates a Jog for the duration of the activation. The Jog settings may be configured at
18
19
F260
– F262.
Emergency Off — Terminates the output signal from the drive and may apply a brake if so configured. The braking
20
21
method may be selected at F603.
DC Braking — Upon activation the drive outputs a DC current that is injected into the windings of the motor to
22
23
quickly brake the motor.
Accel/Decel Switching 1/Accel/Decel Switching 2 — Activating combinations of discrete input terminals
Accel/Decel Switching 1 and 2 allow for the selection of Accel/Decel profiles 1 – 4 as shown below.
See
F504
for more information on this terminal setting.
24
25
A/D SW Terminal
#1
#2
0
0
0
1
1
0
26
27
1
1
1=Terminal Activated
V/f Switching 1/V/f Switching 2 — Activating combinations of discrete input terminals V/f Switching 1 and 2
allow for the selection of a V/f switching profile as listed below.
V/f Switching Terminal
28
29
#1
#2
0
0
1
30
31
1
1=Terminal Activated
Note:
NO/NC = Normally Open/Normally Closed.
234
Terminal Selection Descriptions
A/D Profile Selection
1
2
3
4
V/f Selection
0
1
1
2
0
3
1
4
The settings of the A/D selections 1 – 4 are
performed at F009/F010, F500/F501, F510/
F511, and F514/F515, respectively.
Accel/Decel profiles are comprised of the Accel/
Decel
settings,
Pattern,
and
Frequency.
The 1–4 settings of the V/f Switching selections
are performed at parameters
F170
G9 ASD Installation and Operation Manual
Switching
– F181.

Advertisement

Table of Contents
loading

Table of Contents