Toshiba G9 Installation And Operation Manual page 257

Asd
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc
LED Screen
LCD Screen
Stop Position Retaining
E-25
Error
E-26
CPU2 Fault
E-50/E-51
Sink/Source Setting Error
EEP1
EEPROM Fault
EEP2/EEP3
EEPROM Read Error
EF1/EF2
(Earth) Ground Fault
EPHI
Input Phase Failure
EPHO
Output Phase Failure
ERR2
RAM Fault
ERR3
ROM Fault
ERR4
CPU Fault
ERR5
Communication Error
Gate Array Fault
ERR6
ERR7
Low-Current
Option Device Fault
ERR8
ERR9
Flash Memory Fault
G9 ASD Installation and Operation Manual
Possible Causes
• Load movement while stopped.
F381
setting is too low.
• Encoder malfunction.
• Creep speed is too high.
• CPU malfunction.
• Control board malfunction.
• Improperly positioned Sink/Source jumper on the Terminal board or on an
option device (see J100 at the Terminal PCB of the ASD).
• Sink/Source configuration is incorrect.
• EEPROM write malfunction.
• Make a service call.
• EEPROM read malfunction.
• Make a service call.
• Ground fault at the motor.
• Ground fault at the output of the ASD.
• Current leakage to Earth Ground.
• 3-phase input to the ASD is low or missing at the R, S, or T input terminals.
• 3-phase output from the ASD is low or missing at the U, V, or W output
terminals or at the input to the motor.
• Internal RAM malfunction.
• Make a service call.
• Internal ROM malfunction.
• Make a service call.
• CPU malfunction.
• Control board malfunction.
• Make a service call.
• Communication time out error.
• Communication malfunction.
• Improper or loose connection.
• Improper system settings.
• Main Gate Array is defective.
• Improper Low-Current detection level settings at
• Check installation, connections, and option device manual.
• Flash memory malfunction.
• Make a service call.
F609
– F612.