Table 19. 460-Volt UL Type-1/IP-20 Chassis Standard Ratings Table.
Output Current
Model
100/115% Cont.
Number
(110% Cont.
VT130G9U
 125 HP)
4015
2.7/3.1 A
4025
3.6/4.1 A
4035
5.0/5.8 A
4055
9.1/10.5 A
4080
12.4/14.3 A
4110
15.3/17.6 A
4160
24.0/27.6 A
4220
28.6/32.9 A
4270
35.7/41.1 A
4330
42.0/48.3 A
4400
57.2/65.8 A
4500
68.5/78.8 A
4600
81.5/93.7 A
4750
100.8/115.9 A
410K
138.7/159.5 A
412K
179/196.9 A
415K
215/236.5 A
420K
259/284.9 A
425K
314/345.4 A
430K
387/425.7 A
435K
427/469.7 A
264
Overload Current
Overload Current
150% for 60
150% for 120
Seconds
Seconds
4.1 A
5.4 A
7.5 A
13.7 A
18.6 A
23.0 A
36.0 A
N/A
42.9 A
53.6 A
63.0 A
85.8 A
102.8 A
122.3 A
151.2 A
208.1 A
268.5 A
322.5 A
388.5 A
N/A
471.0 A
580.5 A
640.5 A
Input Voltage
Output Voltage
3-Ph 50/60
3-Ph Variable
± 2 Hz
Frequency
380 – 480 VAC
Input Voltage
(± 10%)
Level (Max.)
G9 ASD Installation and Operation Manual
Typical
Motor HP
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350

Advertisement