5.3 Connect the connection cable

5.3.1 Module

Version: 1.4
The connection cable connects the modules to the control cabinet.
NOTICE
Limited number of turns
The connector may be rotated up to ten times through 180° to
bring it into a safe latching position.
If you turn the connector more than ten times, the cables inside
and the latching mechanism of the connector may be damaged
and the connector may no longer be placed in a safe latching po-
sition.
The connector of the module may be rotated by 90° a maximum of
ten times.
► Plug the connector [1] of the connection cable to the connec-
tor [2] of the module
► Tighten the connector [1] with assembly tool [+]