Assembly and disassembly

7.2 NCT electronics

7.2.1 Checking the air gap

62
───
The NCT electronics are pre-mounted on the mover with two
screws. The air gap between the NCT electronics and the modules
is preset accordingly.
NOTICE
Checking the air gap
The air gap must be checked if a mover is inserted that is not in-
cluded in the scope of delivery or if you have mounted the NCT
electronics on a mover.
If the air gap is not set correctly, there may be problems with en-
ergy transfer and data transmission.
The air gap between the mounted NCT electronics [1] and the motor
module [2] is preset to 1 mm ex factory. The air gap may be reduced
to a minimum of 0.7 mm.
► Insert the feeler gauge blade [1] into the air gap [2] between the
NCT electronics and the module
The air gap must be adjusted if the feeler gauge blade cannot be in-
serted into the air gap.