The vibration levels are measured in accordance with the operational cycle described in
The vibration levels are measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, with vibration switched
EU directive 2000/14/EC on machines equipped for the EU market, with vibration switched
on, on soft polymer material and with the operator's seat in the transport position.
on, on soft polymer material and with the operator's seat in the transport position.
Measured whole-body vibrations are below the action value of 0.5 m/s² as specified in Directive
Measured whole-body vibrations are below the action value of 0.5 m/s² as specified in Directive
2002/44/EC. (Limit is 1.15 m/s²)
2002/44/EC. (Limit is 1.15 m/s²)
Measured hand/arm vibrations also were below the action level of 2.5 m/s² specified in the same
Measured hand/arm vibrations also were below the action level of 2.5 m/s² specified in the same
directive. (Limit is 5 m/s²)
directive. (Limit is 5 m/s²)
The noise level is measured in accordance with the operational cycle described in
The noise level is measured in accordance with the operational cycle described in
EU directive 2000/14/EC on machines equipped for the EU market, on soft polymer
EU directive 2000/14/EC on machines equipped for the EU market, on soft polymer
material with vibration switched on and the operator's seat in the transport position.
material with vibration switched on and the operator's seat in the transport position.
Guaranteed sound power level, L
Guaranteed sound power level, L
Sound pressure level at the operator's ear (platform), L
Sound pressure level at the operator's ear (platform), L
Sound pressure level at the operator's ear (cab), L
Sound pressure level at the operator's ear (cab), L
During operation the above values may differ because of the actual operational
During operation the above values may differ because of the actual operational
conditions.
conditions.
Max 20° or 36%
Max 20° or 36%
2021-03-16

Technical specifications

Vibrations - Operator station

(ISO 2631)

Noise level

wA
wA
pA
pA
pA
pA

Electrical system

Machines are EMC tested in accordance with EN
13309:2000 'Construction machinery'

Slopes

The recommended max slope angle is for a machine
that runs straight on hard, flat surface.
Unstable ground, vibration on, speed and steering the
machine can all cause the machine to topple at
smaller angles than specified here.
4812159701_D.pdf
Technical specifications
55/60kW
55/60kW
74/75kW
74/75kW
91 ±3 dB (A)
91 ±3 dB (A)
85 ±3 dB (A)
85 ±3 dB (A)
106 dB (A)
106 dB (A)
107 dB (A)
107 dB (A)