Emergency Watering (Accessory) - Extra Pump In Pump System; Sprinkler System/Wheels - Freeze Risk; Draining The System - Fayat Group DYNAPAC CC224C Instruction Manual

Table of Contents

Advertisement

1
Figure. Panel on right side of front
frame
1. Extra pump
3
Fig. Wheel rack
1. Rear water tank
2. Sprinkler nozzle
3. Sprinkler system
106
Emergency watering (Accessory) - Extra pump
in pump system
If the water pump stops, an extra pump will keep the
sprinkler system in operation.
Connect the electric cable and water hoses to the
extra pump instead of the standard pump.
The water hoses are connected to the pump with quick
couplings to simplify draining and where appropriate
replacement to a reserve pump (option).
Newer machines can have sprinkler systems with dual
sprinkler pipes and sprinkler pumps as standard.

Sprinkler system/Wheels - Freeze risk

1
Preventive measures when there is a risk of freezing.

Draining the system.

• Close the valve
• Separate the hose
2
• Open the coarse filter
• Loosen the intake to the pump by moving the plastic
clamp to the left and pulling the white plastic adapter from
the pump housing.
• Open the valves in the ends of the sprinkler ramps.
• Allow the fluid to run out and run the sprinkler pump for
about 10 seconds.
4812159701_D.pdf
Maintenance, 10h
2021-03-16