Fig. Compaction meter Evib (DCM
Evib), Asphalt temperature,
Impactometer
1. Compaction meter Evib (DCM Evib)
2. Asphalt temperature
3. Impactometer value
2021-03-16
Alarms received are saved/logged and can be seen by
selecting Display alarms.
Selection of Display alarms.
"ENGINE ALARM"
Saved/Logged engine alarms.
"MACHINE ALARM"
Saved/Logged machine alarms. These alarms come
from the other systems on the machine.
A screen for Compaction meter Evib (DCM Evib)
1
(Optional), Asphalt temperature (Optional) and
Impactometer value can also be shown in the display
when installed on the machine.
2
Asphalt temperature meter (Optional, always
3
included when Compaction meter Evib installed)
Asphalt temperatures are shown either in Celsius or
Fahrenheit. (selected in User settings)
Dual temperature sensors, one front and one rear.
The one that goes first is highlighted and that is the
one to be read to avoid disturbance of moisture from
the drum water spray.
4812159701_D.pdf
Machine description
43