Chapter 9
9.2.4

Setting Frequency Command by Multi-Speed Operation Function

 How to perform multi-speed switching of the frequency command by turning the I/O input
Q
signal on and off?
 The multi-speed operation function allows you to switch between multiple pre-set frequency
A
commands according to the ON/OFF pattern sent to the [CF1] to [CF4] input terminals or the
[SF1] to [SF7] input terminals.
 When multi-speed 1 to 15 is selected, priority is given to the multi-speed command regardless
of the "Frequency input source selection [A001]
settings are turned on, the frequency command for each input terminal function is selected with
the following order or priority: "Force terminal [F-TM] (51)", "Force operation [F-OP] (31)" and
then "Jogging [JG] (06)".
 The following two modes can be selected for the multi-speed operation function according to
the setting of the "Multi-speed operation selection [A019]".
- Binary operation mode: Switches between up to 16 different speeds from 0 to 15 according
to the particular ON/OFF pattern of the four input terminals from [CF1] to [CF4].
- Bit operation mode: Switches between up to eight different speeds from 0 to 7 according to
which of the seven input terminals from [SF1] to [SF7] is turned on.
 When all multi-speed input terminals [CF1] to [CF4] and [SF1] to [SF7] are off, speed 0 operates
!
at the frequency command value set by the "Frequency input source selection [A001]
Code
Output frequency
[F001]
setting or monitor
Multi-speed
[A019]
selection
*1
[A020]
Multi-speed 0
[A021]
Multi-speed
to
1 to 15
[A035]
[C001]
Input terminal
to
function
[C007]
Multistage input
[C169]
determination
time
*1. "2nd-motor control [SET]" target parameter. The second control parameter is also subject to setting.
Item
Changes the value of the currently selected
multi-speed setting.
(For example, when set to multi-speed 2, as
soon as [F001] is changed, [A022] is also
changed to the same value.)
Binary operation mode with up to 16 speeds
Bit operation mode with up to eight speeds
Multi-speed 0 setting which is selected when
the "Frequency input source selection
*1
[A001]
" is set to "Parameter setting(02)".
Multi-speed 1 to 15 setting.
Multi-speed selection 1 to 4 ([CF1] to [CF4]):
These are the multi-speed input terminals
for binary operation (up to 16 speeds).
Multi-speed Bit-1 to 7 ([SF1] to [SF7]):
These are the multi-speed input terminals
for bit operation (up to eight speeds).
Time required to confirm the output
frequency command when multi-speed
switching is performed.
9-2-7
*1
" setting. Please note that when multiple
Description
Inverter Functions
*1
".
Data
0.00,
Minimum frequency to
Maximum frequency (Hz))
00
01
0.00,
Minimum frequency to
Maximum frequency (Hz)
0.00,
Minimum frequency to
Maximum frequency (Hz)
02 to 05
32 to 38
0 to 200 (× 10 ms)

Advertisement