Operation By Run Key On The Keypad - Hitachi WJ Series User Manual

Table of Contents

Advertisement

Chapter 9
9.1.2

Operation by RUN Key on the Keypad

 How to operate the inverter via the keypad during a test run?
Q
 How to operate the inverter via the RUN key on the keypad?
 To start or stop the inverter using the RUN and STOP/RESET keys on the keypad or the optional
A
remote operator (OPE-SR/OPE-SR mini, etc.), set the "RUN command input source selection
*1
[A002]
" parameter to "Keypad (RUN-key) (02)".
 To start operation using the RUN key on the keypad, set the correct direction of operation with
"RUN-key command rotation direction [F004]".
Code
RUN command input
*1
[A002]
source selection
RUN-key command
[F004]
rotation direction
[C021]
Output terminal
[C022]
function
[C026]
*1. "2nd-motor control [SET]" target parameter. The second control parameter is also subject to setting.
 For the inverter to start operation, a frequency command is required in addition to a RUN
!
command.
Item
Operation is started and stopped using the RUN
and STOP/RESET keys on the keypad or optional
remote operator.
Forward rotation operation from the keypad.
Reverse rotation operation from the keypad.
RUN command by keypad [REF]:
This output terminal turns on when inverter
RUN command can be initiated using the RUN
key on the keypad.
9-1-2
Inverter Functions
Description
Data
02
00
01
59

Advertisement

Table of Contents
loading

Table of Contents