Multi-Step Speed Command - Hitachi P1 Basic Instruction Manual

Detroit hoist program v27+
Hide thumbs Also See for P1:
Table of Contents

Advertisement

MULTI-STEP SPEED COMMAND

Multi-Step speed command can be configured up to 16 speeds. Only use multi-step speed command when speed control greater than
3-steps is required. In the multi-step speed command, 4 inputs as a binary combination of 0 (OFF) and 1 (ON) will determine the
command frequency, reference the chart below for configuring the steps and speeds. Use the chart below to configure the use of the
multi-step speed command.
NOTE – The multi-step speed command steps outside of the internal program to determine the speeds during normal operation.
Please make sure that Ab110 & UE-11 match for the low frequency value. Also make sure to set UE-12 to match the high-speed
frequency determined by the multi-speed binary operation.
Speed Control Method
Multi-Step Speed Command
Input Speed Source
Multi-Step Digital Inputs
Set Encoder Limits to Parameters
Muti-Step Speed
1
st
speed
2
nd
speed
3
rd
speed
4
th
speed
5
th
speed
6
th
speed
th
7
speed
th
8
speed
9
th
speed
10
th
speed
11
th
speed
12
th
speed
13
th
speed
14
th
speed
th
15
speed
th
16
speed
CF4
CF3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Parameters
UE-18
AA101
Digital Input 3 | CA-03
Digital Input 4 | CA-04
Digital Input 6 | CA-06
Digital Input 8 | CA-08
UE-33
CF2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Page 10
Frequency
CF1
Parameter
OFF
Ab110
ON
Ab-11
OFF
Ab-12
ON
Ab-13
OFF
Ab-14
ON
Ab-15
OFF
Ab-16
ON
Ab-17
OFF
Ab-18
ON
Ab-19
OFF
Ab-20
ON
Ab-21
OFF
Ab-22
ON
Ab-23
OFF
Ab-24
ON
Ab-25
Values
6
7 = Keypad
03 = CF1
04 = CF2
05 = CF3
06 = CF4
2
NOTE
Set UE-11 to
match Ab110
Set UE-12 to
match the
highest
frequency
set in the
multi-step

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents