Chapter 5
■
No-voltage switch
When using the inverter's internal power supply
Short-
P24
circuit
wire
PLC
L
1
7
Inverter
Connecting the intelligent output terminals to a programmable controller
■
Sink logic
11
12
24 VDC
CM2
Inverter
P24
24 VDC
Short-
PLC
circuit
wire
L
1
7
Inverter
COM
Input module
(EH-XD**, etc.)
5-4-10
When using an external power supply
(Remove the short-circuit wire from the control terminal.)
P24
24 VDC
24 VDC
PLC
L
1
7
Inverter
■
Source logic
CM2
11
12
Inverter
Wire Connection
P24
24 VDC
PLC
24 VDC
L
1
7
Inverter
24 V
DC
COM
Input module
(EH-XD**, etc.)
24 VDC