Basic Paramerter Setting To Drive Motor; Setting Frequency Command Source And Run Command Source - Hitachi SJ700-4000HFU2 Instruction Manual

Hide thumbs Also See for SJ700-4000HFU2:
Table of Contents

Advertisement

Chapter 3
3.5 Basic Parameter Setting to Drive Motor

3.5.1 Setting Frequency command source and Run command source

This section describes how to drive the motor with SJ700D briefly.
The frequency and run command are necessary to drive the motor with the inverter.
In many cases, these sources are set as below;
Setting the frequency
Run and stop
The frequency command and Run command sources can be changed by the parameter A001 (Frequency command
source) and A002 (Run command source) respectively.
In addition to the basic setting mentioned above, there are several options for A001 and A002 setting.
Parameter
A001
Frequency source
A002
Run command source
*) This chapter explains 01(control circuit terminal block) and 02(operator) mainly.
:
(A) Data settings (Digital operator)
(B) Via external analog signals (Control terminal)
:
(A) RUN / STOP key (Digital operator)
(B) Via external signal (Control terminal)
Detail
00(keypad potentiometer)
01(control circuit terminal block)
02(operator)
03(RS485)
04(option 1)
05(option 2)
06(pulse-string input)
07(easy sequence)
10(operation function result)
01(control circuit terminal block)
02(operator)
03(RS485)
04(option 1)
05(option 2)
Data range
3-17
Operation
Initial settings
****FEF3
****FF3
****FUF3
02
01
02
01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj700d-3 series

Table of Contents