Chapter 7
7.2.6

Automatic Registration of Changed Parameter History

 How to know the parameters that have been changed from the default setting?
Q
 When "User-parameter automatic setting function enable [b039]" is set to "Enable (01)", the
A
parameters changed from the default are automatically stored in "User-parameter 1 to 32
selection ([U001] to [U032])" in order. It can also be used as a change history.
 Parameters are stored at the timing when the SET key is pressed. [U001] is the newest changed
parameter and [U032] is the oldest changed parameter.
 If the same parameter is changed, the old memory is erased and new change is stored. If the
number of parameters exceeds 32,the oldest memory in [U032] is deleted.
Code
User-parameter automatic setting function
[b039]
enable
 Note that when [b039] is changed from "Disable (00)" to "Enable (01)", all parameters registered
!
in "User-parameter 1 to 32 selection ([U001] to [U032])" until then are initialized ("no" setting).
Item
7-2-9
Keypad and Related Functions
Description
Disable
Enable