When Replacing Wj200 (Old Model) With Wj-C1 - Hitachi WJ Series User Manual

Table of Contents

Advertisement

Chapter 2
2.2.2

When Replacing WJ200 (Old Model) with WJ-C1

 Even when replacing WJ200 (old model) with a WJ-C1, the basic steps up to operation are the
same as when installing a new one.
 The following is an overview of the procedures for replacing the inverter, assuming that the
input/output signals of the control circuit terminals and other functions are the same as before.
(As there are some differences in functions and control characteristics, be sure to check the
differences and check the operation by test run by referring to "Appendix A.1 Replacement from
WJ200".)
Replacing WJ200 with WJ-C1
1
Confirmation of safety
2
Checking the inverter
Checking the installation
environment, external
3
dimensions and installing the
inverter
Checking and replacing main
circuit wiring
4
Checking and replacing
control circuit wiring
5
Checking how to use keypad
Checking the setting
parameters from WJ200 to
6
WJ-C1 and copying the data
Performing test run, various
adjustments, parameter
7
settings for functions to be
used, etc.
To No. 7 in "2.2.1 When Installing a New Inverter
Outline of This User's Guide/Procedure for Operation
Overview of the checks and main reference sections
Check the precautions necessary for handling the inverter.
"Chapter 1 Safety Instructions/Risks"
Check that there are no problems with the model, enclosed
items, appearance, etc. of the inverter you purchased.
"3.1 Confirmation at the Time of Purchase"
Check the user's guide, instruction manual, etc. of each
device to be replaced, and confirm the differences in
installation dimensions, external dimensions, installation
environment, etc., and install the product correctly.
"Chapter 4 Installation"
"Appendix A.1.1 Comparison of External Dimensions and
Mounting Dimensions"
Wire the main circuit terminal block wirings and control
terminal wirings removed from WJ200 (old model) to the
main circuit terminal block and control terminal on WJ-C1.
At this time, be careful not to mistake the connection place.
Since wiring positions will change, check the contents of
the following sections thoroughly before wiring.
"Chapter 5 Wire Connection"
"Appendix A.1.2 Comparison of Main Circuit Terminal
Block"
"Appendix A.1.3 Comparison of Control Circuit Terminal
Block"
Check how to use keypad of WJ-C1, and then change the
parameter settings or monitor in the following steps.
"7.1 How to Use Keypad"
WJ-C1 is designed to be upwardly compatible with WJ200
Ver. 3.2. To copy parameters, the remote operator WOP or
the setup software "ProDriveNext" can be used. See the
following section for more information.
"Appendix A.1.4 Data Copy from WJ200 to WJ-C1"
Some behaviors are different between WJ200 and WJ-C1.
See the following section for more information.
"Appendix A.1.5 Comparison of Functions of WJ200 and
WJ-C1"
Follow the procedure from step No. 7 in "2.2.1 When
Installing a New Inverter" to make basic settings for the
motor, test run with no load, test run with actual load, and
set various parameters.
2-2-3

Advertisement

Table of Contents
loading

Table of Contents