Daily Inspection And Periodic Inspection; Inverter Inspection List - Hitachi WJ Series User Manual

Table of Contents

Advertisement

Chapter 16

16.2 Daily Inspection and Periodic Inspection

16.2.1

Inverter Inspection List

Inspected
Inspected
part
entry
Check the ambient
Surrounding
temperature, level of
environment
humidity, dust, ... etc..
General
Check that there are no
Whole inverter
abnormal vibrations or
noises.
Check that the main
Power supply
voltage
circuit voltage is normal.
Check the resistance
between the main circuit
and the ground terminals.
(between main circuit and
ground terminals)
General check
Check looseness in
tightening parts.
Check for overheating
traces.
Check for straining in
Conductors
conductors.
and cables
Check for cable coating
Main
damage.
circuit
Terminal block Check for any damage.
Inverter and
converter
Check the resistance
circuits
between all the terminals.
(including
resistors)
Check for capacitor fluid
leakage.
Smoothing
capacitor
Check that the relief valve
does not swell or protude.
No chatter sound while
operating.
Relay
Check contacts for
damage.
Inspection
cycle
Details of inspection
Maintenance and Inspection
Every
Inspection method
Refer to "Chapter 4
Installation".
Check visually and
auditorily.
Measure the line-to-line
voltage of the inverter
main circuit terminals
[R/L1], [S/L2], and [T/L3].
Remove all wires from the
main circuit terminal block
and control circuit terminal
block of the inverter. Then,
shortcircuit the terminals
[R/L1], [S/L2], [T/L3],
[U/T1], [V/T2], [W/T3],
[P/+], [PD/+1], [N/-] and
[RB], and measure between
this shortcircuited part and
the ground terminal.
Check tighten.
Check visually.
Check visually.
Check visually.
Remove all wires from the
main circuit terminal
block of the inverter.
Then measure between
[R/L1]/[S/L2]/[T/L3] -
[P/+]/[N/-], and between
[U/T1]/[V/T2]/[W/T3] -
[P/+]/[N/-] in the 1 Ω
range.
Check visually.
Check auditorily.
Check visually.
16-2-1
Criterion
Tester device
The ambient temperature
and level of humidity are
within the operating
range.
Thermometer,
There are no freeze,
Hygrometer,
condensation, dust,
Data logger
corrosive gas, explosive
gas, flammable gas,
grinding fluid mist,
hydrogen sulfide and salt.
No abnormality.
Multimeter,
Within the allowable AC
Digital
voltage fluctuation.
multimeter
500 VDC
Resistance no less than 5
class
MΩ.
ohmmeter
(megger®)
No abnormality.
No abnormality.
No abnormality.
No abnormality.
Refer to "16.2.4 Checking
the Inverter and
Converter Section".
Analog
Reference for
multimeter
replacement of the
inverter ank converter
6
*3
Start/Stop: 10
cycles
No abnormality.
Approximate replacement
period: 10 years
*1*3*4
No abnormality.
No abnormality.