3–14
"A" Group: Standard Functions
Func.
Code
SRW Display
A005 [AT] selection
AT-Slct
A011 Pot./O–L input active
range start frequency
O-EXS
A012 Pot./O–L input active
range end frequency
O-EXE
A013 Pot./O–L input active
range start voltage
O-EX%S
A014 Pot./O–L input active
range end voltage
O-EX%E
A015 Pot./O–L input start
frequency enable
O-LVL
A016 External frequency
filter time constant
F-SAMP
Multi-speed and Jog Frequency Setting
The SJ200 inverter has the capability to store and output up to 16 preset frequencies to
the motor (A020 to A035). As in traditional motion terminology, we call this multi-speed
profile capability. These preset frequencies are selected by means of digital inputs to the
inverter. The inverter applies the current acceleration or deceleration setting to change
from the current output frequency to the new one. The first multi-speed setting is dupli-
cated for the second motor settings (the remaining 15 multi-speeds apply only to the first
motor).
"A" Function
Name /
Four options, select codes:
00... Select between [O] and
O/OI
[OI] at [AT]
01... [O] + [OI] ([AT] input is
ignored)
02... Select between [O] and
keypad potentiometer
03... Select between [OI] and
keypad potentiometer
The output frequency corre-
sponding to the analog input
range starting point,
0000.0Hz
range is 0.0 to 400.0
The output frequency corre-
sponding to the analog input
range ending point,
0000.0Hz
range is 0.0 to 400.0
The starting point (offset) for
the active analog input range,
range is 0. to 100.
00000%
The ending point (offset) for
the active analog input range,
range is 0. to 100.
00100%
Two options; select codes:
00... Use offset (A011 value)
01... Use 0 Hz
0Hz
Range n = 1 to 8, where n =
number of samples for avg.
00008
Run
Mode
Description
Edit
Defaults
–FEF
–FU
Units
(EU)
(USA)
00
00
Hz
0.0
0.0
Hz
0.0
0.0
Hz
0.
0.
%
100.
100.
%
01
01
—
2.
8.
Sam-
ples