Code
Name
0.00,
Upper frequency
Lower frequency limit, 1st-
A061
limit, 1st-motor
motor to Maximum frequency,
1st-motor (Hz)
0.00,
Upper Frequency
Lower Frequency limit, 2nd-
A261
limit, 2nd-motor
motor to Maximum frequency,
2nd-motor (Hz)
0.00, Minimum frequency to
Lower frequency
A062
limit, 1st-motor
0.00, Minimum frequency to
Lower Frequency
A262
Upper Frequency limit, 2nd-
limit, 2nd-motor
motor
A063 Jump frequency 1 0.00 to 590.00 (Hz)
Jump frequency
0.00 to 10.00 (Hz)
A064
width 1
(100.00 (Hz))
A065 Jump frequency 2 0.00 to 590.00 (Hz)
Jump frequency
0.00 to 10.00 (Hz)
A066
width 2
(100.00 (Hz))
A067 Jump frequency 3 0.00 to 590.00 (Hz)
Jump frequency
0.00 to 10.00 (Hz)
A068
width 3
(100.00 (Hz))
Acceleration stop
A069
0.00 to 590.00 (Hz)
frequency
Acceleration stop
A070
0.0 to 60.0 (s)
time
00: Disable
01: Enable
A071 PID enable
02: Enable (with inverted
PID proportional
A072
0.00 to 25.00
gain
PID integral time
A073
0.0 to 3600.0 (s)
constant
PID derivative
A074
0.00 to 100.00 (s)
gain
A075 PID scale
0.01 to 99.99
00: [Ai2] terminal input
PID feedback
01: [Ai1] terminal input
A076
input source
selection
02: Modbus communication
03: Pulse input
10: Calculation function result
PID deviation
00: Disable
A077
inversion
01: Enable
A078 PID output range 0.0 to 100.0 (%)
00: Disable
PID feed-forward
01: [Ai1] terminal input
A079
input source
selection
02: [Ai2] terminal input
*3. When in WJ200 high frequency compatible mode.
List of Parameters/Modbus Coil/Register Numbers
Data range
Upper frequency limit, 1st-
motor (Hz)
*3
*3
*3
output)
(current input)
(voltage input)
(voltage input)
(current input)
Change
Initial
Set
during
value
value
Register No.
running
124Fh (High)
0.00
1250h (Low)
224Fh (High)
0.00
2250h (Low)
1251h (High)
0.00
1252h (Low)
2251h (High)
0.00
2252h (Low)
1253h (High)
0.00
1254h (Low)
0.50
1255h
1256h (High)
0.00
1257h (Low)
0.50
1258h
1259h (High)
0.00
125Ah (Low)
0.50
125Bh
125Ch (High)
0.00
125Dh (Low)
0.0
125Eh
00
125Fh
1.00
1260h
1.0
1261h
0.00
1262h
1.00
1263h
00
1264h
00
1265h
0.0
1266h
00
1267h
18-2-8
Modbus communication
Data Range
Resolution
0, Lower
frequency
limit, 1st-
motor to
0.01
Maximum
frequency,
1st-motor
0, Lower
Frequency
limit, 2nd-
motor to
0.01
Maximum
frequency,
2nd-motor
0, Minimum
frequency to
Upper
0.01
frequency
limit, 1st-
motor
0, Minimum
frequency to
Upper
0.01
Frequency
limit, 2nd-
motor
0 to 59000
0.01
0 to 1000
0.01
(10000)
*3
0 to 59000
0.01
0 to 1000
0.01
(10000)
*3
0 to 59000
0.01
0 to 1000
0.01
*3
(10000)
0 to 59000
0.01
0 to 600
0.1
0 to 2
-
0 to 2500
0.01
0 to 36000
0.1
0 to 10000
0.01
1 to 9999
0.01
0 to 3, 10
-
0 to 1
-
0 to 1000
0.1
0 to 2
-
Page
9-4-1
9-10-5
9-3-4
9-8-1

Advertisement