6.6
MR-TB26A junction terminal block (multi-axis
servo amplifier) [G] [B]
Usage
Use the junction terminal block (MR-TB26A) with the junction terminal block cable (MR-TBNATBL_M) as a set. To use a
junction terminal block, mount it to the DIN rail.
The terminal numbers on a junction terminal block correspond with the pin numbers on the CN3 connector of a servo
amplifier. The terminal symbol S is for the shield.
Servo amplifier
CN3
Ground the junction terminal block cable using the S terminal of the junction terminal block.
Specifications
Item
Rating
Usable wires
Tool
Stripped length
6 OPTIONS AND PERIPHERAL EQUIPMENT
306
6.6 MR-TB26A junction terminal block (multi-axis servo amplifier) [G] [B]
Cable length
05: 0.5 m
1: 1 m
Junction terminal block cable
(MR-TBNATBL_M)
MR-TB26A
AC/DC 32 V 0.5 A
Stranded wire
0.08 mm
Solid wire
φ0.32 mm to 1.2 mm
Wire insulator OD
φ3.4 mm or less
210-619 (WAGO) or equivalent
210-119SB (WAGO) or equivalent
5 mm to 6 mm
Junction terminal block
MR-TB26A
2
2
to 1.5 mm
(28 to 14 AWG)