• Caution for passing the home position (reference mark)
An interval for turning on home position (reference mark) signal of the linear encoder has a certain width. (Specifications differ
depending on the linear encoder.)
MR-J5 Partner's Encoder User's Manual
Example: When the Z-phase is recognized at startup
Home position signal
A recognized as
ON position
The position where LZ (Encoder Z-phase pulse) is turned on depends on the direction of home position passing. In cases
where each homing is required to be completed at the same position, such as dog type homing, start homing with the same
direction.
• Point to note for linear encoder without home position (reference mark)
For the linear encoder without home position (reference mark), LZ (Encoder Z-phase pulse) of the servo amplifier is not
output. Check the specifications of the controller for whether LZ (Encoder Z-phase pulse) is necessary or not for homing.
Absolute position linear encoder
When using an absolute position linear encoder, the data set type homing can also be carried out.
• For proximity dog type homing
For a proximity dog type homing, the nearest reference home position after proximity dog off is the home position. The linear
encoder home position can be set in any position. LZ (Encoder Z-phase pulse) is output based on the set value of [Pr. PL01.2
Homing stop interval setting].
Linear servo motor speed
0 mm/s
ON
Proximity dog signal
OFF
Reference home position
Linear servo motor position
*1 This can be changed with [Pr. PL01].
11 USING A LINEAR SERVO MOTOR
528
11.4 Basic functions
B
A
B recognized as ON position
Homing speed
*1
1048576 pulses
1048576 pulses × n
Linear encoder home position
Homing direction
Creep speed
Home position