Using servo amplifier with DC power supply input
When using a fuse instead of the molded-case circuit breaker, use the one having the specifications given in this section.
For main circuit power supply (1-axis servo amplifier)
Servo
Molded-case circuit breaker
amplifier
Frame, rated current
Power factor
improving
reactor is not
used
MR-J5-10_
30 A frame 5 A
MR-J5-20_
30 A frame 5 A
MR-J5-40_
30 A frame 10 A
MR-J5-60_
30 A frame 15 A
MR-J5-70_
30 A frame 15 A
MR-J5-100_
30 A frame 15 A
(3-phase power
supply input)
MR-J5-100_
30 A frame 15 A
(1-phase power
supply input)
MR-J5-200_
30 A frame 20 A
MR-J5-350_
30 A frame 30 A
MR-J5-500_
50 A frame 50 A
MR-J5-700_
100 A frame 75 A
*1 Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of
80 ms or less.
For main circuit power supply (multi-axis servo amplifier)
• MR-J5W2-_
Total output of
Total
rotary servo
continuous
motors
thrust of linear
servo motors
300 W or less
Over 300 W
150 N or less
600 W or less
Over 600 W
Over 150 N
1 kW or less
300 N or less
Over 1 kW
Over 300 N
2 kW or less
720 N or less
*1 Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of
80 ms or less.
• MR-J5W3-_
Total output of
Total
rotary servo
continuous
motors
thrust of linear
servo motors
450 W or less
150 N or less
Over 450 W
Over 150 N
800 W or less
300 N or less
Over 800 W
Over 300 N
1.5 kW or less
450 N or less
*1 Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of
80 ms or less.
Voltage AC
[V]
Power factor
improving
reactor is used
30 A frame 5 A
240
30 A frame 5 A
30 A frame 5 A
30 A frame 10 A
30 A frame 10 A
30 A frame 10 A
30 A frame 15 A
30 A frame 20 A
30 A frame 30 A
50 A frame 50 A
60 A frame 60 A
Total output of
Molded-case circuit breaker
direct drive
Frame,
motors
Rated current
30 A frame 5 A
100 W or less
30 A frame 10 A
Over 100 W
30 A frame 15 A
252 W or less
Over 252 W
30 A frame 20 A
838 W or less
Total output of
Molded-case circuit breaker
direct drive
Frame,
motors
Rated current
30 A frame 10 A
252 W or less
30 A frame 15 A
Over 252 W
30 A frame 20 A
378 W or less
6.11 Molded-case circuit breakers, fuses, magnetic contactors
Fuse
Class
Current [A]
Voltage DC
[V]
T
10
400
15
20
30
40
60
80
Fuse
Voltage
Class
Current
AC
[A]
[V]
240
T
15
20
20
30
Fuse
Voltage
Class
Current
AC
[A]
[V]
240
T
20
20
30
6 OPTIONS AND PERIPHERAL EQUIPMENT
Magnetic
*1
contactor
DUD-N30
DUD-N60
Magnetic
*1
contactor
Voltage
AC
[V]
400
DUD-N30
Magnetic
*1
contactor
Voltage
AC
[V]
400
DUD-N30
333
6