Multifunction Regeneration Converter (Fr-Xc-(H)); Precautions; Servo Amplifier Settings; Capacity Selection - Mitsubishi Electric MELSERVO MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO MR-J5 Series:
Table of Contents

Advertisement

6.4

Multifunction regeneration converter (FR-XC-(H))

For details on the multifunction regeneration converter (FR-XC-(H)), refer to "FR-XC Instruction Manual (IB-
0600668ENG)".

Precautions

• Set the FR-XC-(H) to the common bus regeneration mode by turning on the switch 1 of the function selecting switch (SW2).
• Do not apply power to the main circuit power supply terminals (L1/L2/L3) of the servo amplifier. Doing so may fail the servo
amplifier and the FR-XC-(H).
• Connect the polarities of the DC power supply between the FR-XC-(H) and the servo amplifier correctly. Failing to do so
may fail the FR-XC-(H) and the servo amplifier.
• Regenerative capacity cannot be enhanced even if two or more FR-XC-(H) are connected.
• When using the FR-XC-H, the rated voltage and the permissible fluctuation of the input power supply must be within the
following range.
Rated voltage: 3-phase, 380 to 480 V, 50 Hz/60 Hz
Permissible fluctuation: 3-phase, 323 to 528 V, 50 Hz/60 Hz
• To prevent malfunctions, separate the wiring for DC power supplies and signals.

Servo amplifier settings

When using the FR-XC-(H), set the parameters as follows.
• [Pr. PA02.0-1]: 01/[Pr. PA02.4]: 0
• [Pr. PA04.2]: 0/[Pr. PA04.3]: 0

Capacity selection

Selection conditions
The multifunction regeneration converter FR-XC-(H) can be used with 200 V class servo amplifiers with capacities of 100 W to
7 kW and 400 V class servo amplifiers with capacities of 600 W to 7 kW. Use the following conditions to select a multifunction
regeneration converter.
• Number of servo amplifiers to be connected to one FR-XC-(H) is 10 or less
• Total capacity of servo amplifiers [kW] ≤ Total capacity of servo amplifiers that can be connected to the FR-XC-(H) [kW]
• Effective value of total output power of servo motors [kW] ≤ Continuous output of the FR-XC-(H) [kW]
• Maximum value of total output power of servo motors [kW] ≤ Instantaneous maximum output of the FR-XC-(H) [kW]
Item
Rated capacity [kW]
Maximum number of connectable servo amplifiers
Total capacity of connectable servo amplifiers [kW]
*1
Continuous output [kW]
Instantaneous maximum output [kW]
*1 Values in parentheses are when six servo amplifiers or less are connected.
FR-XC-(H)-_
7.5K
11K
7.5
11
10
*1
3.5 (5.5)
5.5 (7.5)
3.5 (5.5)
5.5 (7.5)
11.25
16.5
15K
22K
30K
15
22
30
7.5 (11)
22
30
7.5 (11)
18.5
22
22.5
33
45
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.4 Multifunction regeneration converter (FR-XC-(H))
6
37K
55K
37
55
37
55
30
45
55.5
82.5
295

Advertisement

Table of Contents
loading

Table of Contents