Generated Loss - Mitsubishi Electric MELSERVO MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO MR-J5 Series:
Table of Contents

Advertisement

Generated loss

Servo amplifier generated heat
The following tables indicate the losses generated by servo amplifiers under rated load. For thermal design of an enclosed
type cabinet, use the values in the tables in consideration for the worst operating conditions including environments and
operation patterns. The actual amount of generated heat depends on the frequency of operation and will be between the "At
rated output" and "At servo-off" values.
200 V class
• 1-axis servo amplifier
Servo amplifier
MR-J5-10_
MR-J5-20_
MR-J5-40_
MR-J5-60_
MR-J5-70_
MR-J5-100_
MR-J5-200_
MR-J5-350_
MR-J5-500_
MR-J5-700_
• Multi-axis servo amplifier
Servo amplifier
MR-J5W2-22_
MR-J5W2-44_
MR-J5W2-77_
MR-J5W2-1010_
MR-J5W3-222_
MR-J5W2-444_
*1 The values stated for heat generated by the servo amplifier do not take into account the heat generated during regeneration. To
calculate heat generated by the regenerative option, refer to the following.
Page 269 Regenerative optionPage 269 Regenerative option
5 CHARACTERISTICS
184
5.2 Power supply capacity and generated loss
Servo amplifier-generated heat [W]
At rated output
25
25
35
40
50
50
90
130
195
300
Servo amplifier-generated heat [W]
At rated output
Connected to one axis: 30
Connected to two axes: 40
Connected to one axis: 40
Connected to two axes: 60
Connected to one axis: 55
Connected to two axes: 90
Connected to one axis: 55
Connected to two axes: 90
Connected to one axis: 35
Connected to two axes: 45
Connected to three axes: 55
Connected to one axis: 45
Connected to two axes: 65
Connected to three axes: 85
*1
At servo-off
15
15
15
15
15
15
20
20
25
25
*1
At servo-off
20
20
20
20
25
25
Area required for heat
2
dissipation [m
]
0.5
0.5
0.7
0.8
1.0
1.0
1.8
2.6
3.9
6.0