9.8

Wiring the SBC output

This function only guarantees that the power supply for the mechanical brake is correct. It cannot detect brake
wear. Check the mechanical brake periodically to ensure it is functioning correctly.
To use SBCS (SBC output), connect it to the electromagnetic brake of the servo motor. Wire the system so that the
electromagnetic brake activates when SBCS (SBC output) turns off. There is no need to use the MBR (Electromagnetic brake
interlock) of the servo amplifier. For information on the operation sequence when the SBC function is used, refer to "SBC
function" in the following manual.
MR-J5 User's Manual (Function)
Servo amplifier
SDOCOM
SDO1A
SDO1B
*1 The circuit should be shut off in conjunction with the emergency stop switch.
*2 Do not use the 24 V DC interface power supply for the electromagnetic brake.
9 USING FUNCTIONAL SAFETY [G] (EXCULUDING MR-J5-_G_-HS_)
470
9.8 Wiring the SBC output
24 V DC
CN8
RA1
CN8
RA2
ALM
(Malfunction)
RA1
RA2
*2
24 V DC
Servo motor
*1
B1
B
U
B2