2. Selecting 900AE/AO Limits/Power Mode Settings
This sub-menu allows you to set ultrasonic power when a certain % of the power
(measured against the power rating of your 900M) has been reached. For example, if you
have a 910M (1000 watts) and set Peak Power to 50%, ultrasonic power will shut off
when power reaches 500 watts.
Setting
Choices
Function
PK POW END WLD
= OFF (D)
Do not select Peak Power to end the weld
cycle.
= ON
Select Peak Power to end the weld cycle.
PEAK POWER
= 1 - 110 %
(D = 1%)
Select the % of Peak Power.
3. Displaying 900AE/AO Reports
This sub-menu allows you to view details of your particular system. You cannot make
selections in this sub-menu.
Reports
Function
PEAK POWER = 0 . 0 %
Indicates Peak Power of the previous weld.
PALM BUTTONS = MAINTAINED /
MOMENTARY
Indicates PALM BUTTON status
SER NUM morxxxx - xxxx
Indicates your 900M's MBOS serial number
POWER SUPLY = xxxxW
Indicates your 900M's power rating
MBOS VER. = xx.xx
Indicates your 900M's operating system version