' Selecting 900M — Handgun Mode Setup Menus Settings
The following three sub-menus are available:
1. Limits/Power Mode
2. Report
3. Configure
Each sub-menu gives you setting choices described in the tables below. The letter (D) by
a choice indicates that this is the default choice. Refer to Figure 4-6 for a view of the
menu showing all settings. Refer to Appendix D: Key Terms for definitions of acronyms
and terms used in these menus.
1. Selecting Handgun Mode Limits/Power Mode Settings
This sub-menu allows you to set ultrasonic power when a certain % of the power
(measured against the power rating of your 900M) has been reached. For example, if you
have a 910M (1000 watts) and set Peak Power to 50%, ultrasonic power will shut off
when power reaches 500 watts.
Setting
Choices
Function
PK POW END WLD
= OFF (D)
Do not select Peak Power to end the weld
cycle.
= ON
Select Peak Power to end the weld cycle.
PEAK POWER
= 1 - 110 %
(D = 1%)
Select the % of Peak Power.
2. Displaying Handgun Mode Reports
This sub-menu allows you to view details of your particular system. You cannot make
selections in this sub-menu.
Reports
Function
PEAK POWER = 0 . 0 %
Indicates Peak Power of the previous weld.
PALM BUTTONS = MAINTAINED /
MOMENTARY
Indicates PALM BUTTON status
SER NUM xxxxxxx - xxxx
Indicates your 900M's MBOS serial number
POWER SUPLY = xxxxW
Indicates your 900M's power rating
MBOS VER. = xx.xx
Indicates your 900M's operating system version
900M P/S Operator's