Setting
TEC
Mode with
TIME
settings
The following table describes how to set TEC mode with TIME settings, the first time you
use this mode. Please note that once you select settings, the digits you see in the display
windows will differ from those shown here.
Once you have set the desired value, press TIME/ENERGY together to reenter "READY TEC
MODE 1X".
Press this key
This happens
On the
STATUS
display, you see
1. TIME/ENERGY at the
same time
You access TEC mode
"READY TEC MODE 1X"
2. Top saEcT
You access TIME settings
"050"
"WELD TIME /mSEC"
3. Top SELECT again
You access the minimum
setting
"050"
"WELD TIME /mSEC"
4. Top SELECT again
You access 25% of the
maximum setting
"2.50"
"WELD TIME /SECONDS"
5. Top SELECT again
You access the minimum
setting
"050"
"WELD TIME /mSEC"
6. 1113/DOV7N arrows
You change settings by
005/025 msec increments
For example, "075"
"WELD TIME /mSEC"
7. TIME/ENERGY
together
The unit retum to READY state
"READY TEC MODE 1X"
There are two ways to exit from weld modes:
1. Press the flashing mode key or keys.
2. After pressing any uP / DOWN arrow key(s), press the appropriate SELECT key.
Storing Settings: After fine-tuning all your welding settings, you can store them in
memory as a preset for recall at a later date. (See instructions for storing and recalling
weld settings in Section 4.6.) Once you have performed a weld cycle or activated a
PALM
BUTTON,
the current weld settings are automatically stored in preset 0. You can store up
to 20 presets.