Features; Inputs - Branson 900M Series Manual

Table of Contents

Advertisement

1.3 900M features
900Ms provide the following features:
• A microprocessor-based programmer module to provide controls for setting the
parameters of the weld cycle and displaying cycle and alarm information.
• An alphanumeric status display to indicate weld cycle progress and warning of
problems encountered.
• A System Protection Monitor/Autotune (SPM/AT) to monitor and protect the system to
ensure maximum reliability. The SPM/AT will terminate ultrasonic energy if the system
is operated under adverse conditions.
• A 24 VDC connection on the back panel to connect to external controls and devices
for monitoring cycles and sorting suspect parts.
• Two data link connections to communicate with external Branson devices through the
Accessory Interface Module in the 900M.
• Self-diagnostics during startup to provide a status message on the
STATUS
Display.
• External communications through an optional External Communications Interface
device (ECI) to drive external devices such as printers, host computers, or modems.
1.4 Inputs
The 900M's functioning also depends on inputs and controls. These are switches, sensors,
and signals used to start and monitor the system through the weld cycle. Many of these
inputs and controls are discussed in detail in the relevant actuator manuals. Since they are
often referred to in subsequent sections, brief descriptions follow.
Input
Where Located
Function
PALM BUTTONS
(PB1/PB2)
Base, or customer
supplied signal
Start a weld cycle.
EMERGENCY STOP
(E-sToP)
Base, or customer
supplied signal
Aborts the current weld cycle and
prevents any further welds from
being started until you release the
switch.
UPPER LIMIT SWITCH
(us)
Actuator
Signals the 900M control circuits that
the carriage has returned to the top
of its stroke
(READY
state).
PRETRIGGER SWITCH
(vrs)
Actuator
Starts ultrasonics prior to the horn
contacting the part.
TRIGGER SWITCH (ms)
Actuator
Indicates that the required amount of
force has been applied to the part
and signals the power supply to
activate ultrasonic power.
Introduction