4.6
Other Functions
.r
"*..
This section covers the following tasks:
• storing weld settings
recalling weld settings
restoring default settings
controlling the display
displaying counters
understanding and reset alarms
testing the welding system
manually tuning the 900M
4.6.1 Storing Weld Settings
At the end of each weld cycle, the 900M automatically stores the weld settings used to
make that cycle in a location called "preset 0." The 900M has 20 presets (1 — 20) which
you can use to store weld settings that you might need to reuse.
After you have selected your weld settings and run them satisfactorily, store the selected
settings as follows:
Step
What you do
What happens
1
Press STORE.
"STORE AT PRESET 0 "' appears on the STATUS
display (the * indicates that the preset already
contains data).
2
Press Slow UP / DOWN.
You scroll through the presets.
3
Select a preset.
You stop at the selected preset.
4
Press STORE again.
"STORING PARAMETERS" then "VERIFYING
PARAMETERS" appears on the STATUS display.
5
The 900M returns to READY state.
Press RESET at any time to exit without storing new settings.
Note: You can erase and overwrite a preset containing data (*) by selecting it and
overwriting it with your new settings.