Setting
Choices
Function
MAX FORCE =
10-1000 lbs
(D=10)
Select the maximum force required during the
welding portion of a weld cycle.
TRS DIST RANGE
= OFF (D)
Do not select a distance range within which the
Tits force condition must be met. (This can be
used to detect missing parts.)
= ON
Select a distance range within which the Tits
force condition must be met. (This can be used
to detect missing parts.)
TRS MIN POS =
0.0100-6 in
(D=0.0100)
Select the minimum distance the horn must travel
from Ins before ms force is encountered.
TRS MAX POS =
0.0100-6 in
(D=0.0100)
(D)
Select the maximum distance the horn must
travel from uts before 'tits force is encountered.
PK POW END WLD
OFF (D)
Do not select peak power input to end the weld
and proceed to hold.
ON
Select peak power input to end the weld and
proceed to hold.
PEAK POWER =
1-110 %
(D=1%)
Select the value of peak power used to end the
weld and proceed to hold.
4.
Displaying 900AES/AOS Reports
This sub-menu allows you to view details of your particular system. You cannot make
selections in this sub-menu.
Reports
Function
TOT COL POS = 0.0000
Indicates the total Collapse position of the last
weld.
FNL ABS POS = 0.0000
Indicates the final Absolute position of the last
weld.
DOWN SPEED = 0.00
Indicates the maximum velocity achieved during
the down stroke of the last weld.
GAUGE PRESSURE = 0
Indicates the gauge pressure of the last weld.
PEAK POWER = 0 . 0 %
Indicates the Peak Power % of the last weld.
Operation
4-42