Setting
TIME
Mode with
ENERGY
Settings
The following table describes how to make settings the first time you use this mode.
Please note that once you select settings, the digits you see in the display windows will
differ from the default values shown here.
Once you have set the desired value, press
TIME
to reenter "READY TIME MODE 1X".
Press this key
This happens
On the
STATUS
display, you see
1. TIME
You access
TIME
mode
"READY TIME MODE 1X"
2. Middle SELECT
You access + energy limit
settings
"OFF"
"JOULES + LIMIT"
3. Middle
SELECT
again
You access the minimum
setting
"001"
"JOULES + LIMIT"
4. Middle SELECT
again
You access 25% of the
maximum setting
"7.50"
"KJOULES + LIMIT"
5. Middle
SELECT
again
You disable the setting
"OFF"
"JOULES + LIMIT"
6. Bottom
SET FCT
You access - energy limit
settings
"001"
"JOUI-F-S - LIMIT"
7. Bottom
SELECT
again
You access the minimum
setting
"001"
"JOULES -
LIMIT"
8. Bottom
SELECT
again
You access 25% of the
maximum setting
"7.50"
"KJOUIRS - LIMIT"
9. Bottom
SELECT
again
You disable the setting
"OFF"
"JOULES
-
LIMIT"
10. Bottom
SELECT
again
You access the minimum
setting
"001"
"JOULES - LIMIT"
11. UP/DOWN
arrows
You change settings by
001/005 joule increments
For example, "002" or "006"
"JOULES - LIMIT"
12. TIME
or
SET
FCT
The unit return to
READY
state
"READY TIME MODE 1X"
There are two ways to exit from weld modes:
1. Press the flashing mode key or keys.
2. After pressing any
UP / DOWN
arrow key(s), press the appropriate SELECT key.
Storing Settings: After fine-tuning all your welding settings, you can store them in
memory as a preset for recall at a later date. (See instructions for storing and recalling
weld settings in Section 4.6.) Once you have performed a weld cycle or activated a PALM
BUTTON, the current weld settings are automatically stored in preset 0. You can store up
to 20 presets.