INSPECT TEST PART
OVERLOAD CONDITION
Weld Part
LOADING
20% - 100Z
OVERLOAD
Monitor POWER BARGRAPH and Displays
Tuna P/S
Reduce pressure
Reduce dynamic trigger force
Use lower gain booster
Overweld
Acceptable Weld
Underweld
UNDERWELD
Increase weld time or pressure
Use higher gain booster
Increase dynamic trigger force
Increase down speed
Increase amplitude
OVERWELD
Reduce weld time or pressure
Use lower gain booster
Reduce dynamic trigger force
Reduce down speed
Decrease Amplitude
IRecord Parameters
a. Welding in Time Mode
Figure 4-7 illustrates the weld cycle procedure and options for Time mode. The
STATUS
display will show current status messages throughout the setup procedure.
Figure 4-7
Time Mode
Weld
Cycle
Select booster
Align system
i
Set
Set
Set
Set
Set
Set
Set
stroke length
down speed
mechanical stop
dynamic trigger force
Pretriggsr (option)
Lower Limit (option)
amplitude (if used)
Set
Set
Set
Set
Set
pressure
weld time
hold time
A.B. delay (if req.)