4.6
Other Functions
This section covers the following tasks:
• storing weld settings
•
recalling weld settings
•
restoring default settings
•
controlling the display
•
displaying counters
•
understanding and reset alarms
•
testing the welding system
•
manually tuning the 900M
4.6.1 Storing Weld Settings
At the end of each weld cycle, the 900M automatically stores the weld settings used to
make that cycle in a location called "preset 0." The 900M has 20 presets (1 — 20) which
you can use to store weld settings that you might need to reuse.
After you have selected your weld settings and run them satisfactorily, store the selected
settings as follows:
Step
What you do
What happens
1
Press
STORE.
"STORE AT PRESET 0 *" appears on the
STATUS
display (the ' indicates that the preset already
contains data).
2
Press Slow
UP / DOWN.
You scroll through the presets.
3
Select a preset.
You stop at the selected preset.
4
Press
STORE
again.
"STORING PARAMETERS" then "VERIFYING
PARAMETERS" appears on the
STATUS
display.
5
The 900M returns to
READY
state.
Press
RESET
at any time to exit without storing new settings.
Note: You can erase and overwrite a preset containing data CO by selecting it and
overwriting it with your new settings.
Operation
4-62