5. Additional Remote TEACH Procedures

5.1. TEACH Analog Output and Discrete Output Switch Points
Together
Use the following procedure to teach identical Analog Output and Discrete Output switch points at the same time using the remote input. This
feature is not available using the buttons.
1)
Access the TEACH mode.
Single-pulse the remote input.
2)
Present the target.
Action
Present the switch point one target.
3)
TEACH the sensor.
Three-pulse the remote input.
4)
Present the target.
Action
Present the switch point two target.
5)
TEACH the sensor.
Single-pulse the remote input.
5.2. TEACH Analog Output and Discrete Output Midpoints
Together
Use the following procedure to teach an identical Analog Output 12 mA (5 V) point and Discrete Output midpoint (switch point) at the same time
using the remote input. This feature is not available using the buttons. Note that if the window sizes and/or offsets were set independently (using
the buttons), the windows taught using the following procedure could be different.
Action
T
Action
T
T
T
Action
T
© Banner Engineering Corp. www.bannerengineering.com
"RMT TCH" and the current measurement value display.
"RMT TCH"and the target's measurement value display.
"TchA&D1 Teaching" displays while the sensor is being
taught.
TEACH Accepted
The new value displays on the second line of the display,
T
flashes, and then "TchA&D2" and the current measurement
value display.
T
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2, and "RMT TCH"
displays.
"TchA&D2" and the target's measurement value display.
"TchA&D2 Teaching" displays while the sensor is being taught.
TEACH Accepted
The new value displays on the second line of the display,
flashes, and the sensor returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2, and "RMT TCH"
displays.