4. Sync Master/Slave
Two LTF sensors may be used together in a single sensing application. To eliminate crosstalk between the two sensors, configure one sensor
to be the master and one to be the slave. In this mode, the sensors alternate taking measurements and the response speed triples.
1)
Configure the first sensor as the master; navigate: MENU > INPUT > Type > SyncMstr.
2)
Configure the second sensor as the slave; navigate: MENU > INPUT > Type > SyncSlve.
3)
Connect the gray (input) wires of the two sensors together.
If using a combination of Class 1 and Class 2 laser models, the Class 1 laser model must be used as the master.
33