Red 
Input 3 
 

Configuring a Sensor

The K30 Pro Optical Sensor has three Teach modes. These modes are indicated with a Teach Status color. 
The Signal Level color flashes in between the Teach Status color. The color of the Signal Level depends on the signal strength of the target:
Green: Best signal, accepts Teach 
Yellow: Acceptable signal, can accept Teach 
Red: Poor signal, rejects Teach 

Remote Input

Use the remote input to program the sensor remotely. 
The remote input provides limited programming options and is Active High in PNP mode (V+ to brown wire), or Active Low in NPN mode (V+
to blue wire). For Active High, pulse the gray or yellow input wire to V+ (10 V DC to 30 V DC). For Active Low, pulse the gray or yellow input
wire to ground (0 V DC). 
The remote input wire is enabled by default. Pulse the remote input wire 7 times or use the Banner Pro Editor software to enable or disable 
the feature. When the remote input feature is enabled, pulse the remote input according to the diagram and the instructions provided in this
manual. Remote teach can also be performed using the button on the Pro Converter Cable. 
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds. 
Exit remote programming modes by cycling power or by waiting for 30 seconds. 
NOTE:  If a factory reset is performed through the Banner Pro Editor Software, the remote input wire becomes enabled 
(factory default setting). If the sensor is returned to factory defaults by using the remote input wire, the input wire re­
mains enabled and the rest of the settings are restored to factory defaults. 
Remote Teach 
Use the following procedure to teach the Set Point. 
1.
 Pulse the remote input: 
3x ­ Object Teach: The indicator alternates between a blue Teach Status color and the Signal Level color. 
4x ­ Background Teach: The indicator alternates between a magenta Teach Status color and the Signal Level color. 
5x ­ Window Teach: The indicator alternates between a cyan Teach Status color and the Signal Level color. 
2.
Present the Set Point. 
3.
Teach the Set Point. 
 Single pulse the remote input. 
June 22, 2023
Continued from page 2
Yellow 
Green 
 
 
Action 
T
 
© Banner Engineering Corp.
K30 Pro Optical Sensor Quick Start Guide
Cyan 
Blue 
Teach Accepted 
The indicator stops flashing and the device returns to operation. 
Teach Not Accepted 
The Signal Level color turns red during the teach procedure, and then the
indicator stops flashing. 
Retry teaching the set point. 