2. Sensor Installation

: Handle the sensor with care during installation and operation. Sensor windows soiled by fingerprints, dust, water, oil, etc. may create stray
NOTE
light that may degrade the peak performance of the sensor. Blow the window clear using filtered, compressed air, then clean as necessary using
70% isopropyl alcohol and cotton swabs or water and a soft cloth.

2.1. Mount the Device

1.
If a bracket is needed, mount the device onto the bracket.
2.
Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten the mounting
screws at this time.
3.
Check the device alignment.
4.
Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.

2.2. Wiring Diagrams

1
3
4
Load
2
4-20 mA
5
shield
* User-configurable PNP/NPN setting
Figure 1: Analog Current Model

2.3. Connecting to RSD1

The following diagram depicts the connection of the LTF to the optional RSD1 accessory.
LTF
Double Ended Shielded
MQDEC3-503SS
MQDEC3-506SS
MQDEC3-515SS
MQDEC3-530SS
Use these cordsets to connect the RSD1 to the LTF sensor or to other devices, such as PLC inputs, IO-Link masters, or control systems.
+
12-30V dc
D_Out
A_Out
Input
Figure 3: LTF to RSD1
© Banner Engineering Corp. www.bannerengineering.com
1
12-30V dc
3
4
D_Out
Load
2
A_Out
0-10V
5
Input
shield
* User-configurable PNP/NPN setting
Figure 2: Analog Voltage Model
RSD1
S
ENSOR
+
Key
1
4
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
Double Ended Shielded
MQDEC3-503SS
MQDEC3-506SS
MQDEC3-515SS
MQDEC3-530SS
Flying Lead Shielded
MQDEC2-506
MQDEC2-515
MQDEC2-530
I
NSTALLATION
2
3
5
4

Advertisement