RDLS-8..D
RDLS-8..D Pinout
Brown
Ch1a
Orn/Blk
n.c.
Orange
n.c.
White
Ch1b
Black
Ch2b
Blue
n.c.
Gn/Ye
n.c.
Violet
Ch2a

11.6 Remote TEACH Fixed Blanking (Wiring)

Programming Key Switch Location
See
A key-actuated switch provides some supervisory control since the key can be removed from the switch. The Programming
Key Switch must be located:
Located outside the guarded area,
Located to allow the switch operator full unobstructed view of the entire defined area, and
Protected against unauthorized or inadvertent operation.
DELSEF-81D Wiring. RD-to-M12 QD double-ended 300 mm (1') cordset in combination with EZA-RBK-1 Remote Blanking
Key Switch, and DEE2R-8..D Doubled-ended cordsets to extend the position.
EZ-SCREEN LS
DELSEF-81D
RDLS-8..D Wiring. RD-to-flying lead cordset can be used to directly wire to a SPDT (form C) switch and a separate
indication device. Take precautions to prevent unused wires from shorting to ground or to other sources of energy (for
example, terminate with wire-nut).
78
Open
Bn
Vi
Bk
Wh
Take precautions to prevent unused wires from
shorting to ground or to other sources of
energy (for example, terminate with wire-nut).
Figure 47. Monitoring two positive-opening safety switches
on page 47 for complete instructions.