Sensor Menu Full Map

3.3. Remote Input

Use the remote input to program the sensor remotely. The remove input is disabled by default. Activate remote input using the buttons to navigate
to the Input Type menu option.
The remote input provides limited programming options and is Active Low by default. For Active Low, connect the gray input wire to ground (0 V
DC), with a remote switch connected between the wire and ground. To use the Active High function, configure the sensor for Active High using
the buttons on the sensor, then connect the gray input wire to V+ (12 to 30 V DC). Pulse the remote input according to the diagram and the
instructions provided in this manual.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by holding the remote input low for > 2 seconds, or waiting for the automatic 60-second timeout, or by pressing
and holding Escape for 2 seconds. The sensor returns to Run mode without saving any new settings.
7
Sensor Menu
MENU A_OUT
MENU D_OUT
MENU INPUT
MENU MEASURE
MENU DISPLAY
MENU INFO
MENU RESET
Figure 3: Sensor Menu Basic Map
© Banner Engineering Corp. www.bannerengineering.com
(See Sensor Menu Full Map for the complete map)
Access analog output settings
Access discrete output settings
Select input line settings (remote TEACH, trigger mode, etc.)
Select response speed and trigger measurement
Select display units, zero reference, shift, and orientation
View sensor information
Reset to factory defaults