3. Sensor Programming

Program the sensor using the buttons on the sensor or the remote input (limited programming options).
From Run mode, use the buttons to access the Quick Menu and the Sensor Menu. See
more information on the options available from each menu. For TEACH options, follow the TEACH instructions.
In addition to programming the sensor, use the remote input to disable the buttons for security, preventing unauthorized or accidental program-
ming changes. See
Remote Input

3.1. Quick Menu

The sensor includes a Quick Menu with easy access to view and change the analog and discrete output switch points. Access the Quick Menu
by pressing Down or Up from Run mode. When in the Quick Menu, the current distance measurement displays on the first line and the menu
name and the analog value alternate on the second line of the display. Press Enter to access the switch points. Press Down and Up to change
each digit. Press Enter to move right one digit. After reviewing each digit, press Enter again to save the new value and return to the Quick Menu.
Press Cancel to ignore any changes made if only some digits have been changed.

3.2. LTF Sensor Menu (MENU)

Access the Sensor Menu by pressing Enter from Run mode. The Sensor Menu is also accessible from the Quick Menu: navigate to MENU and
press Enter. The Sensor Menu includes several submenus that provide access to view and change sensor settings and to view sensor informa-
tion.
for more information.
Access
Quick Menu
Figure 1: Accessing the menus
See
Quick Menu for the LTF
Quick Menu
Run
Mode
4mA Pt (value)
20mA Pt (value)
SPt1 Pt (value)
SPt2 Pt (value)
Figure 2: Quick Menu Map (Window Mode)
© Banner Engineering Corp. www.bannerengineering.com
Quick Menu for the LTF
from Run Mode
Access
Sensor Menu
See
Sensor Menu (MENU)
set value with
Save setting
and return to
Quick Menu
Cancel and
return to
Quick Menu
access Sensor
MENU
Menu (Top Menu)
* In Setpoint Mode,
SPt1 Pt is replaced by SPt
and SPt2 Pt is not available.
S
ENSOR
and
Sensor Menu (MENU)
or
P
ROGRAMMING
for
6