Input Type; Input Active; Measure Menu (Measure) - Banner LTF Series Instruction Manual

Time of flight laser distance sensor
Hide thumbs Also See for LTF Series:
Table of Contents

Advertisement

S
P
ENSOR
ROGRAMMING
MENU INPUT
Select Menu Item
or
Press to Save Setting
Go Back to Parent Menu
or
Press and Hold to Go Back
to Run Mode

3.7.1. Input Type

The Type option sets the input type.
Navigate: MENU > INPUT > Type
Remote Input: Not available
Default: Disabled
Input Type
Teach
LasrEnbl
Trigger
SyncMstr
SyncSlve
Disabled

3.7.2. Input Active

The Active option sets the active state of the remote input. Use the Active options to change the active input to Low or High.
Navigate: MENU > INPUT > Active
Remote Input: Not available
Default: Low
Input Active
Low
High

3.8. Measure Menu (MEASURE)

Use this menu to view or change the:
Speed
Trigger
25
INPUT Type
INPUT Active
Figure 15: Input Menu map
The remote input is used to TEACH and program the sensor.
The remote input is used to control when the laser emitter is On/Off.
The remote input is used to trigger advanced measurements To enable advanced measurements, the Input Type option must
be set to Trigger (see ).
The remote input is used as the Master Sync output to an attached Slave sensor (see ).
The remote input is used as the Slave Sync input from an attached Master sensor (see ).
The remote input is disabled. (Default)
The remote input detects low (0 V) inputs and high-to-low transitions. (Default)
The remote input detects high (V+) inputs and low-to-high transitions.
© Banner Engineering Corp. www.bannerengineering.com
Type Teach
Type LasrEnbl
Type Trigger
Type SyncMstr
Type SyncSlve
Type Disabled
Active Low
Active High
Description