Troubleshooting - Banner LTF Series Instruction Manual

Time of flight laser distance sensor
Hide thumbs Also See for LTF Series:
Table of Contents

Advertisement

T
ROUBLESHOOTING

7. Troubleshooting

Message/Indicator
Fail/Out of Range
Fail/OfSt Out of Range
MIN Wnd xx mm (xx in)
xxxx < NEAR
xxxx > FAR
OutRnge
< NEAR
Power LED is flashing green
All LEDs are flashing
Type Sync Slave
39
Description
The TEACH failed, the target is out of range. The target
might have moved out of range after the TEACH process
began.
The TEACH failed. The target is in range but the offset
value caused the setpoint(s) to be out of range.
The adjusted or taught window size is too small; the
minimum window size is displayed.
The threshold (xxxx) is less than the minimum sensing
range. xxxx could be 4mA Pt (0V Pt), 20mA Pt (10V Pt) or
SPt1.
The threshold (xxxx) is greater than the maximum sensing
range. xxxx could be 4mA Pt (0V Pt), 20mA Pt (10V Pt) or
SPt2.
The target is out of range, too dark, or the sensor is not
measuring.
During RUN mode the target is detected, but is inside the
NEAR measuring range.
The sensor input is set to laser enable and the input is not
active.
The laser shuts off, the Power LED flashes green, the
Output LEDs flash amber at 1 Hz, and the display is blank.
The sensor has experienced a fault.
The slave mode sensor does not see the master's pulse.
© Banner Engineering Corp. www.bannerengineering.com
Resolution
TEACH the target within the measurement range.
Adjust the offset value or target distance to keep the setpoint(s)
within the measurement range.
The sensor automatically adjusts the window size to maintain the
minimum window size and completes the adjust or TEACH
operation.
The desired window size is maintained, but the usable portion of the
window is restricted to be within the defined sensing range.
The desired window size is maintained, but the usable portion of the
window is restricted to be within the defined sensing range.
Move the target within the measurement range.
The sensor can reliably detect targets up to the face of the sensor,
and the Discrete Output state is valid. The Analog Output cannot be
used to measure distances inside the NEAR measuring range.
See
Input
Type.
Contact Banner Engineering to resolve.
Make sure that the master mode sensor is configured and
functioning properly. Check the input wire connection between the
master and slave.