Time of flight laser distance sensor
Hide thumbs Also See for LTF Series:
Table of Contents

Advertisement

S
P
ENSOR
ROGRAMMING
Default: Sample
Trigger
Sample
Average
Maximum (Max)
Minimum (Min)
Range
TrackMax
TrackMin
Input
Signal
Inactive
REMOTE
INPUT
Active
(Active Low shown)
Signal
REMOTE
INPUT
(Active Low shown)
27
The current distance at the time of the trigger event. (Default) The Analog Output tracks the sample values during the measuring
period.
The average distance since the last trigger event.
The maximum distance since the last trigger event.
The minimum distance since the last trigger event.
The difference between the maximum and minimum distance since the last trigger event. For additional information on the
Range measurement behavior when the maximum or minimum distance is outside of the taught setpoints, see
page
14.
The maximum distance since the last trigger event. The Analog Output tracks new maximum values during the measurement
period.
The minimum distance since the last trigger event. The Analog Output tracks new minimum values during the measurement
period.
Measuring Period
Hold
Measurement
Input
Measuring Period
Inactive
Active
Hold
Measurement
© Banner Engineering Corp. www.bannerengineering.com
Description
Measuring Period
Hold
Measurement
Figure 18: Sample
Measuring Period
Hold
Measurement
Figure 19: Average
Loss of Signal on
Sample
(t)
Average
(t)