Factory Default Settings for the Q5X Analog with IO-Link
Factory default settings
TEACH Mode
Response Speed
Averaging
Slope
Zero Reference Location
Zero Reference Location after a TEACH
Display Units
Output Type Polarity
Loss of Signal
Input Wire Function
Trigger Mode
Display Read
Ch2 Output
Ch2 Adaptive Tracking
Ch2 Window Size
Ch2 Output Timing Delays

Manual Adjustments

Manually adjust the sensor switch point using the + and - buttons.
From Run mode, press either + or - one time.
1.
The selected channel displays briefly, then the current switch point value flashes slowly.
2.
Press + to move the switch point up or - to move the switch point down.
After 1 second of inactivity, the new switch point value flashes rapidly, the new setting is accepted, and the sensor re­
turns to Run mode.
NOTE: When FGS mode is selected, manual adjustment moves both sides of the symmetrical threshold
window simultaneously, expanding and collapsing the window size. Manual adjustment does not move the
center point of the window. 
NOTE: When dual mode is selected, after the TEACH process is completed, use the manual adjustment
to adjust the sensitivity of the thresholds around the taught reference point. The taught reference point is a
combination of the measured distance and returned signal intensity from the reference target. Manual ad­
justment does not move the taught reference point, but pressing + increases the sensitivity, and pressing -
 decreases the sensitivity. When re­positioning the sensor or changing the reference target, re­teach the 
sensor. 

Remote Input

Remote input is available from the Channel 1 menu. Set inPt to Set.
34
Setting
Two­point TEACH
3.0 ms
Average 1 measurement for analog output
Positive slope
Zero displayed at the front of the sensor
Zero point is at the front of the sensor or maximum detection range
Centimeters (with decimal point at < 60 cm)
IO­Link on pin 4
3.5 mA (current models)
0 V (voltage models)
Remote TEACH input inactive
Average measurement
Display on
Light operate
Adaptive tracking off
Automatic
No delays enabled
Factory Default